Ta繊維強化型(Nb,Ti)3Sn線の冷凍機冷却下における熱的安定性
Thermal Stability of Cryocooled Ta-Fiber-Reinforced Nb3Sn Composite Wire

冷凍機冷却したTa繊維補強型Nb3Sn線のMQE (Minimum Quench Energy)を温度,印加磁場10から14.5 T の範囲,通電電流密度の組み合わせを変えて測定した.温度マージンは各負荷条件下での常電導転移までの温度的余裕である.この結果,各温度において様々な負荷条件下で測定されたMQEは,温度マージンと比例関係にあることがわかった.

岡山大学 工学部:山本 剛,渡部賢司,村瀬 暁
東北大学 金属材料研究所:西島 元,渡辺和雄
日立電線:岩城源三

The MQE for the cryocooled Ta-fiber-reinforced Nb3Sn composite wire was measured experimentally in various load conditions as the parameter of the temperature, applied magnetic-field, 10 - 14.5 T, and the transport current density. Temperature margin which is the abscissa axis is a difference between the operating temperature and the superconducting to normal transition temperature. It was found that MQE-temperature margin characteristics at each temperature showed a straight line even if loaded conditions varied.

Faculty of Engineering, Okayama University: T. Yamamoto, K. Watanabe, S. Murase
IMR, Tohoku University: G. Nishijima, K. Watanabe
Hitachi Cable, Ltd.:G. Iwaki
Reference: T. Yamamoto, K. Watanabe, S. Murase, G. Nishijima, K. Watanabe, A. Kimura,